FW 05.01.00 and SW 07.01.00 Director 2/64 Installation Guide (AA-RSNGC-TE/958-000289-001, June 2003)
Installing and Configuring the Director 2/64
82 Director 2/64 Installation Guide
2. Double-click the Director 64 icon. The Hardware View page for the selected
Director 2/64 displays, as shown in Figure 38. In the example, there are link
incidents (yellow triangles) and director operational is indicated by the green
circle in the alert panel.
3. Check director status at the Hardware View page and complete one of the
following steps:
a. If the director displays as operational (no FRU alert symbols and a green
circle at the alert panel), go to “Set Director Date and Time” on page 83.
b. If director operation displays as degraded or a director failure is indicated
(FRU alert symbols and a yellow triangle or red diamond at the alert
panel), refer to the HP StorageWorks Director 2/64 Service Manual.
Failed—Director-to-server communication has been established,
but the director failed and requires immediate service. Go to
step 2.
Status Unknown—The director status is unknown because of a
network communication failure between the director and HAFM
server. Go to step 2.
Table 5: Director Operational States and Symbols (Continued)
Operational State Symbol