FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director 2/64 Installation Guide (AA-RSNGE-TE/958-000289-003, March 2005)

Overview18
Front view
Figure 1 shows Director 2/64 components accessible from the front of the director. Component
descriptions follow the figure.
Figure 1 Director components—front
CTP2 card
The Director 2/64 ships with two Control Processor (CTP2) cards. The active CTP2 card initializes
and configures the director after power on, and contains the microprocessor and associated logic
that coordinate director operation. The second CTP2 card serves as a backup. A CTP2 card
provides an Initial Machine Load (IML) button on the faceplate. When the button is pressed and
held for three seconds, the director reloads firmware and resets the CTP2 card without switching off
power or affecting operational fiber-optic links.
Each CTP2 card also provides a 10/100 megabit per second (Mbps) RJ-45 twisted pair connector
on the faceplate that attaches to an Ethernet Local Area Network (LAN).
Each CTP2 card provides System Services Processor (SSP) and Embedded Port (EP) subsystems. The
SSP subsystem runs director applications, communicates with director ports, and controls the RS-232
maintenance port and 10/100 Mbps ethernet port. The EP subsystem provides Class F processing,
and manages frame transmission to and from the Serial Crossbar Assembly (SBAR). In addition,
CTP2 cards provide non-volatile memory for storing firmware director configuration information,
1 Power and system error LEDs
2 UPM cards
3 Power supplies
4 Cable management assembly
1
5 Front bezel
6 CTP2 cards
1. Provided in rack-mount kits HP 9000, HP 10000, and HP 11000 Series only.