FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director 2/64 Installation Guide (AA-RSNGE-TE/958-000289-003, March 2005)
Installing and configuring the director34
Install the director in a rack
The following sections provide instructions for installing the director in either the HP 9000, HP
10000, and HP 11000 Series rack; or in the HP system/e and industry-standard 19-in racks.
Required tools
Obtain the following tools:
• For a HP system/e and industry-standard 19-in rack:
•#2 Phillips screwdriver
•Torque screwdriver
• For an HP 9000, HP 10000, and HP 11000 Series rack:
•#2 Phillips screwdriver
• Torx head driver T25
Tips for installing more than one switch
Review the following tips:
• Install the first director in the lowest position of the rack allocated for switches.
• If installing more than one switch, HP recommends installing an optional PDU in the bottom of
the rack. HP ships two PDU power cords with the director.
• Install additional switches in position directly above one another.
• Make sure to connect power cables as you install each individual switch.
4
Rail Tray Kit (part number: A6534-60016):
• One rail tray
• Two mounting brackets
• Two M3 Tinnerman nuts
• Four Torx T25 16 mm M5 SEM screws
2, 3, 5
Mounting hardware:
Rack-mount brackets (part number: A6534-60014) containing:
• Two front mounting brackets (5)
• Two rear mounting plates (2)
• Two rear angle brackets (3)
Switch rack hardware (part number: A6534-62002):
• Twenty-two Torx T25 16 mm M5 SEM screws (includes extras)
• Eighteen sheet metal nuts
• Eight 10-32 Phillips flat-head screws (includes extras)
Table 5 Parts for Installing in an HP System/e and industry-standard 19-inch rack
Label Item