FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director 2/64 Installation Guide (AA-RSNGE-TE/958-000289-003, March 2005)

Installing and configuring the director40
b. Move to the front of the switch and secure each front mounting bracket with the three screws
provided.
Figure 14 Securing the rear angle brackets
7. Using a torque driver, torque the screws to 22 in/lb.
8. Connect the remaining ends of the PDU power cords to separate PDUs (if installed), as shown in
Figure 15; otherwise, connect the two standard AC power cords.
NOTE: HP recommends installing an optional PDU in the rack. HP ships two PDU power cords
with the director.
WARNING! HP power cords are provided for each director power supply. To prevent personal
injury by electric shock, use only the supplied power cords. Also, verify that the facility power
receptacle is the correct type, supplies the required voltage, and is properly grounded.