FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director 2/64 Installation Guide (AA-RSNGE-TE/958-000289-003, March 2005)
Director 2/64 installation guide 49
1. Carefully position the switch in the front of the rack and onto the rail tray, and slide the switch
back on the rails until the front mounting brackets are against the front rack columns. Figure 24
illustrates using a lifting jack to position the switch.
Figure 24 Positioning the switch in the rack
2. Mount the switch in the rack (Figure 25):
a. On one side at the back of the switch, position an angle bracket (2) so that the threaded
holes (1) are against the slots (5) of the rear mounting bracket and the angled side face out.
b. Insert the screws (6) through the rear mounting bracket slots into the threaded nuts of the
angle bracket.
c. Insert a second set of screws (4) through the angle bracket and the rail column into the sheet
metal nuts on the back rail (3).
d. Repeat step 2a through step 2c for the other side at the back of the switch.
e. At the front of the rack, insert the screws through the front mounting brackets into the sheet
metal nuts installed in the rail columns in step 1 of ”Prepare the front and rear rack columns”
on page 45.