FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director 2/64 Installation Guide (AA-RSNGE-TE/958-000289-003, March 2005)
Installing and configuring the director50
f. Tighten all screws.
Securing the switch to the rack
Figure 25 Securing the switch to the rack
3. At the front of the rack, insert the screws through the front mounting brackets into the sheet metal
nuts installed in the rail columns in step 1 of AC power connections
WARNING! HP power cords are provided for each director power supply. To prevent personal
injury by electric shock, use only the supplied power cords. Also, verify that the facility power
receptacle is the correct type, supplies the required voltage, and is properly grounded.
4. Connect the equipment rack power cords to separate (for redundancy) facility power sources,
providing single-phase, 120 to 240 VAC current.
Sliding shelf installation—for an HAFM appliance only
This section only applies to a Management Station. Use the following procedure to install sliding
shelf brackets (Figure 26):
1. Select a U slot above the switch. (HP recommends the U slot immediately above the switch.
However, other U slots above the switch may also be used.)
2. On each rack rear column, locate the hole (1) that is 2 holes up from the EIA number of the
selected U slot (3).
3. Line up this hole with the threaded hole on the sliding shelf bracket's side.
4. Using a screw (2), attach bracket (5) to the rack.