FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director 2/64 Installation Guide (AA-RSNGE-TE/958-000289-003, March 2005)

Installing and configuring the director54
3. Wrap the cable bundles with the cable restraints (1) in two positions on each side of the rack to
maintain clearance for power supply access (3).
Figure 29 Recommended cable management
Power-on self test
Use the following steps to run a Power-on self test (POST):
1. Power on the PDUs (if used).
2. At the bottom rear of the director, set the power switch (circuit breaker) to the Up position.
The director powers on. The following occurs during POST:
Amber LEDs on both CTP2 cards and all UPM cards illuminate momentarily.
The green LED on each CTP2 card (active and backup) turns O
N as the card is tested and
UPM cards are tested.
Green LEDs associated with Fibre Channel ports sequentially illuminate as the ports are
tested.
3. After successful POST completion, the green power LED on the front bezel, green LED on the
active CTP2 card, and green PWR OK LEDs on both power supplies remain O
N.
4. If a POST error or other malfunction occurs, refer to the HP StorageWorks Director 2/64 service
manual.
Configure director network information
Use the following sections to configure the director’s network addressing scheme.