FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director 2/64 Installation Guide (AA-RSNGE-TE/958-000289-003, March 2005)
Installing and configuring the director62
7. Click OK.
Verify communication between the director and HAFM appliance
Follow these steps to check director-to-server communication:
1. At the HAFM application main window (physical map or product list), inspect the shape and
color of the status symbol associated with the director icon. Table 6 explains these symbols.
2. Right-click the Director 64 icon. A pop-up menu for the selected director appears.
3. Check director status at the Hardware View page (Figure 40), and complete one of the
following steps:
• If the director is displayed as operational (no FRU alert symbols), go to ”Configuring feature
key” on page 86.
• If director operation is displayed as degraded or a director failure is indicated (FRU alert
symbols and a yellow triangle or red diamond at the alert panel), refer to the HP
StorageWorks Director 2/64 service manual.
Table 6 Director operational states and symbols
Operational state Symbol
Operational—Director-to-server communication has been established, the
director is operational, and no failures are indicated.
No status
symbol
Degraded—Director-to-server communication has been established, but the
director is operating in degraded mode and requires service. This condition
is typical if a port or redundant FRU fails. Go to step 2.
Failed—Director-to-server communication has been established, but the
director failed and requires immediate service. Go to step 2.
Status Unknown—The director status is unknown because of a network
communication failure between the director and HAFM appliance. Go to
step 2.