FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director 2/64 Installation Guide (AA-RSNGE-TE/958-000289-003, March 2005)
Installing and configuring the director74
A check in the box indicates that the port is blocked. Blocking the port prevents the attached
device from communicating with the director. A blocked port continuously transmits the
offline sequence.
Figure 46 Configure Ports dialog box
c. Select the 10-100 km box to enable extended distance buffering for a port.
A check in the box indicates the extended distance operation up to 100 kilometers (through
repeaters) is enabled.
NOTE: If the director supports BB_Credits by port, the 10-100 Km column is replaced by an RX BB
Credit column.
d. If the director supports BB_Credits by port, right-click the RX BB Credit column.
The RX BB Credits dialog box appears.
NOTE: The port must be offline to change the BB_Credit field.
• For switches without buffer pools, this dialog box allows you to:
Set all... to set all ports to a single value (the Set All RX BB Credits dialog box appears
for you to enter the RX BB value)
Set all to maximum to set all ports to a maximum BB_Credit value. Maximum allowable
port BB_Credit values vary by director
• For switches with buffer pools, this dialog box allows you to:
Set all... to set all ports to a single value (the Set All RX BB Credits dialog box appears
for you to enter the RX BB value)
Distribute to evenly distribute the pool buffers among all ports.