FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director 2/64 Installation Guide (AA-RSNGE-TE/958-000289-003, March 2005)
Installing and configuring the director82
NOTE: Click Previous if you need to return to the previous screen.
Figure 54 New Threshold Alerts dialog box—second screen
6. Enter a percentage from 1 through 100 for % utilization.
When throughput reaches this percentage of port capacity, a threshold alert will occur.
7. Enter the amount of cumulative minutes in which the % utilization should exist during the
notification interval before an alert is generated. The valid range is from 1 to the interval value
set in step 8.
You can also select At any time if you want an alert to occur whenever the set % utilization is
reached.
8. Enter the interval in minutes in which throughput is measured and threshold notifications can
occur. The valid range is 5 minutes to 70,560 minutes.
9. Click Next.