FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director Element Manager User Guide (AA-RTDUD-TE, March 2005)
Director Element Manager user guide 147
Factory-default values may vary, depending on the firmware release installed in your director. For
a list of values, refer to the HP StorageWorks Director 2/64 service manual for the Director 2/64
and the HP StorageWorks Director 2/140 service manual for the Director 2/140.
Table 7 Data default values
Configuration Description Default
Identification Director Name NULL string
Director Description “Fibre Channel Director”
Director Contact “End User Contact (please configure)”
Director Location “End User Contact (please configure)”
Ports Port Names NULL strings
Port Blocked States Unblocked
Extended Distance
(10–100 km)
Disabled
RX BB Credit Disabled
LIN Alerts Disabled
Port Address Port number plus 4
Director Addressing IP Address 10, mac[3], mac[4], mac[5] converted to word32
MAC addresses are set in hexadecimal; IP addresses in
decimal. A MAC address of 08 00 88 20 00 57 will be
reset to an IP address of 10.32.0.87.
Subnet Mask 255.0.0.0
Gateway Address 0.0.0.0
MAC Address PROM value
Operating
Parameters
Preferred Domain ID 1
Buffer-to-Buffer Credit 16
R_A_TOV 10 seconds (100 tenths)
E_D_TOV 2 seconds (20 tenths)
Director Priority 254
Insistent Disabled
Rerouting Delay Enabled
Domain RSCNs Disabled
Suppress Zoning RSCNs Disabled