FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director Element Manager User Guide (AA-RTDUD-TE, March 2005)

Director Element Manager user guide 85
G Port Module—For the fiber channel port card, the following acronyms may display to
indicate the card’s port technology:
GLSL—G_Port, long wave, single mode LC connector, 1 Gigabit
GSML—G_Port, short wave, multimode, LC connector, 1 Gigabit
GXXL—G_Port, mixed mode, LC connector, 1 Gigabit
FPM—G_Port, small form factor pluggable (SFP) optics, fibre port module, 1 Gigabit
UPM—G_Port, small form factor pluggable (SFP) optics, universal port module, 2
Gigabit
GSFM—G_Port, short wave, small form factor, multimode, 1 Gigabit
GLSR—G_Port, short wave, single mode, MT-RJ connector, 1 Gigabit
GXXR—G_Port, mixed mode, MT-RJ connector, 1 Gigabit
GXXL—G_Port, mixed mode, LC connector, 1 Gigabit
Cooling FAN—Fan module.
PWR—Power supply module.
Position—A number representing the FRU chassis position. The chassis (slot) position for a
nonredundant FRU is 0. The chassis positions for redundant FRUs are 0 and 1. For the Director
2/64 chassis, port positions are 0–63. For the Director 2/140 model, port positions are
0–127 and 132–143. Note that for the Director 2/140, ports 128–131 are internal ports and
are not available for external connections.
Status—The FRU status (Active or Backup).
Part Number—The FRU part number.
Serial Number—The FRU serial number.
To display the FRU Properties dialog box for an FRU:
Click the FRU’s row and select Product > FRU > FRU Properties.
Or
Double-click an FRU.