FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director Release Notes (AA-RTDVG-TE/958-000276-007, March 2005)

When downgrading to a release prior to 07.00.00-84, any modifications to the port
RX BB_Credit settings using the new enhanced port configuration capability must be
changed back to a configuration supported by older firmware. This is necessar y
to allow the configuration to comply with previous releases configuration database.
Firmware 07.00.00-84 services verify compatibility and prevent downloads until the
configuration conflict is resolved.
For procedures to download firmware to the switch or director using the HAFM Element
Manager interface or EWS interface, refer to the following:
The switch or director Installation and Service Manual. This publication
provides complete procedures for obtaining firmware from the H P web site and
downloading firmware to the switch or director using HA FM.
The switch or director Element M anager online h elp and User Manual. These
includes instructions for downloading firmware to the switch or director using the
HAFM interface.
EWS User Manual. This provides procedures for downloading firmware to
the switch or director.
EWS online help. This provides procedures for downloading firmware to the
switch or director.
Downgrading directly to a release before 06.00.00 from 07.00.00-84 is not allowed.
To downgrade to a release before 06.00.00, you must first downgrade to 06.YY.ZZ.
Upgrades and downgrades are supported only from one major release to the next, such
as from 06.xx.xx to 07.00.00-84. If EWS is used for upgrades and downgrades, and
this rule is not followed, errors occur and there may be a disruption to at tached devices.
Downgradingtorelease6.0withthePreferredPathfeatureconfiguredcouldcauseloss
of this function. HP recommends that Preferred Path be disabled before downgrading.
To do this, deselect the check box for Enable Preferred Pat h in the Configure
Preferred Paths dialog b ox.
NOTE:
The Director 2/140 and the Edge Switch 2/24 cannot be downgraded earlier than
04.01.00, and the Edge Switch 2/12 cannot be downgraded earlier than 05.05.00.