FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director Release Notes (AA-RTDVG-TE/958-000276-007, March 2005)

Please contact your local HP technical resource to confirm compatibility with d evices
in your SAN before upgrading to this firmware version.
For more information on upgrading software versions, refer to the HP StorageWorks
HA-Fabric Manager User Guide. Thefeaturesofthissoftwareversionaredetailedin
the a ccompanying manuals listed in section Otherdirectordocumentation.
Zone FlexPar feature
Because zoning is managed on a fabric-wide basis, all switches and directors in the
fabric must maintain the same zoning configuration. This configuration is maintained
automatically through the Fibre Channel protocol.
To keep this information current , RSCN messages are sent through the fabric to inform
attached devices when zoning changes occur, when devices become available, or
when devices become unavailable. In the case where devices become available or
unavailable, RSCNs are sent only to the devices in the same zone. Zoning changes,
however, trigger RSCNs to be sent to all of the devices in the fabric. As fabrics grow
larger and larger, the quantity of RSCNs from zoning changes can create congestion
and disrupt devices, causing them to pause normal activity to determine the status
of the other devices. This can occur even if the new device is not zoned to talk to
the other devices in the fabric.
WiththeZoneFlexParfeatureenabled,RSCNmessagesforazoningchangeare
handled like RSCNs for availability/unavailability changes. Specifically, RSCNs are
restricted to only those devices sharing at least one common zone with the device that
changed. This way, only devices that are impacted by the change in connectivit y
receive RSCNs.
The Zone FlexPar feature is available in both Open Fabric 1.0 and Homogeneous
Fabric 1.0 Interop modes, as well as in environments with loop-attached devices. In
Homogeneous Fabric 1.0 mode, the default zone is treated like any other zone, and
RSCNs are sent only to the affected d evices if the default zone is enabled or disabled.
A PFE key is not required for the Zone FlexPar feature, and it can be enabled or
disabled through CLI for a specific switch. When upgrading to firmware 07.00.00
or installing a new switch with firmware 07.00.00 the feature is enabled by default,
allowing it to work immediately. If the Zone FlexPar feature is not enabled on all
switches in the fabric, the restricted RSCN distribution only applies for devices attached
to switches with the feature enabled.
Enhanced SANtegrity Security Suite
SANtegrity Security Suite enhanced features include authentication support for device
login, interswitch connections and management interfaces. The Secure Access features
are included as a standard par t of the SANtegrity Security Suite in firmware 07.00.00.
16