FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director Release Notes (AA-RTDVG-TE/958-000276-007, March 2005)
Firmware 05.03.01-01 is available for the Edge Switch 2/24, and firmware
05.05.01-01 is available for the Edge Switch 2/12. These versions are installed only
ontheEdgeSwitch2/24andEdgeSwitch2/12,andonlywhentheseswitchesare
placed in a M-Series SAN running 05.02.00 firmware. A copy of these versions of
firmware, are contained on the HP StorageWorks edge switch documentation and
firmware CD (Par t Number 524-000001-005) .
Reinstalling feature licenses
Feature licen
ses (or keys) must be reinstalled af ter performing a factor y reset on a
director to r
egain use of the licensed features (e.g., SANtegrity Binding).
Disconnecting the null modem cable
Always log out and disconnect the null m odem cable from the serial maintenance por t
when not in use or when the switch is reset.
CTP controls port lights
Por t lights on the edge switch and director products are controlled by the CTP
functionality. Certain a ctivities such as firmware updates, IPLing the CTP, or switching
over to the backup CTP (director) can cause these port lights to extinguish momentarily
until control is reasserted by the C TP. The actual Fibre Channel traffic is not affected
during the
se tim es.
Ethernet switch support
With firmware 06.00.00 and later, customers can now connect the management
port on edge switches and directors to Ethernet switches or hubs. Prior to firmware
06.00.00, only connections to Ethernet hubs were qualified and supported.
Full Volatility
Full Volatility is an optional feature of firmware 06.00.00 and later that is enabled
with a f
eature key. The Full Volatility feature is designed to support high-security
environments, which require that customer data n ot be retained by the edge switch or
director after power off.
22