FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director Release Notes (AA-RTDVG-TE/958-000276-007, March 2005)

Thefeatureconfiguresaswitchordirectorsothatnoframedataisstoredafterapower
off. Without Full Volatilit y, if the switch or director experiences a fault condition, a
dump of the embedded memory space is captured into nonvolatile memory. This dump
retains the last 30 frames transmitted from and last four frames transmitted to the
embedded port. With Full Volatility installed, this dump does not occur when a fault
condition occurs. Although this limits the amount of d iagnostic information available
for potential problem resolution, the vast majority of p roblems are typically resolved
without the dump files.
Contact your sales representative to purchase a feature key for Full Volatility.
CLI threshold alerts
With firmware 0
6.00.00 and later, the CLI allows you to set and monitor Throughput
Threshold Alerts (TT As).
CLI show.even
tLog command
With firmware 06.00.00 and later, the CLI show.eventLog command has been
enhanced. The comma nd now displays a Link Incident log and Event log.
MIHPTO value
With firmware 06.00.00 and later, the internal Missing Interrupt Handler Primary Time
Out (MIHPTO) value has been changed from 15 seconds to 3 minutes.
EWS enhancements
With firmware 06.00.00 and later, EWS enhancem ents include support for mana ging
the SANtegrity Binding feature and Enterprise Fabric mode, and providing the Link
Incident log and the Open Trunking log.
Preferred Path suppor t
With firmware 07.00.00 and later, this allows users who are not using HA FM to
configure preferred data paths through the EWS interface. A preferred path is an ISL
data path between multiple fabric elements (directors and switches) that users can
configure using the source and exit ports of the origination fabric element, and the
domain ID of the destination fabric element.
HP StorageWorks Director release notes
23