FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director Release Notes (AA-RTDVG-TE/958-000276-007, March 2005)

Zoning enhancement to reduce fabric congestion
In Homogeneous Fab
ric mode, an enhancement was added to reduce unnecessary
fabric congestio
n when performing fabric-wide zoning operations that impact the Default
Zone. This enhan
cement limits the number of members allowed in the Default Zone to
64. When the firmware detects a zoning operation that would cause the member count
in the Default Zone to exceed 64 (such as deactivating an active zone set that has mo re
than 64 members) , the operation is aborted and the user interface (HAFM 8.6 or EWS)
displays the following message: Zoning request denied: Operation will
cause the Defa
ult Zone to exceed its limit of 64 members.
NOTE:
This limit is d
isabled when the switch parameter Suppress Zoning RSCNs on Zone set
activations check box is enabled.
Kno wn issues
This section describes the known issues related to the Director 2/64 and Director 2/140.
HSG80 transparent mode not supported with IBM AIX
Use of an HSG80 with IBM AIX is restricted to operating the HSG80 in M u ltibus mode
with the Director 2/64 and Director 2/140. Transparent mode is not supported at
this time.
Workaroun
d
None.
HSG80 transparent mode not recommended with controller in SCSI-3 mo de
with HP-UX operating systems
Due to an issue with nonexistent duplicate LUNs being displayed with the HP-UX
operating systems, the HSG80 controller is restricted to SCSI-2 mode of operation
when set to Transparent failover mode.
SCSI-3 mode of operation in Multibus failover mode is fully supported with the use of
Secure
Pa th software, 3.0 or later versions.
HP StorageWorks Director release notes
25