FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director Release Notes (AA-RTDVG-TE/958-000276-007, March 2005)

Workaround
None.
ISL disconnect causes NOS error with the OpenVMS operating systems
When an ISL connection is physically removed between directors or switches, the Fibre
Channel Adapter model FCA2354 transmits a Not Operational Sequence (NOS) error.
This is observed as an entry in the HAFM appliance Link Incident log for the port in
which the FCA2354 is attached. The director’s Hardware View also displays a yellow
triangle icon over the port that detected this incident. The fabric op eration or data
movement is not disrupted by these incidents, and you can clear a ler ts from these
incidences using the following procedure.
Workaround
Use these steps
to clear the incident alerts.
1. At the HAFM Hard
ware View,clicktheportmoduletoopenthePort Card
View.
2. Right-click on the port with the yellow triangle icon, and choose Clear Link
Inciden t Alert(s).
Support for speed Auto-Negotiate
Auto-negotiate is supported. However, HP recommends that the port speed for E_Ports
(for Interswitch Links, or ISLs) be set to a spec ific port speed (1Gb/sec or 2Gb/sec,
as appropriate for the speed of the directors or edge switches being connected) instead
of to Negotiate. Using a specific port speed decreases the time for a fabric build
in response to some perturbation event in the fabric. Similarly, setting a specific port
speed for N_Ports also decreases fabric build time. However, setting a specific port
speedforN_Portsisnotrequired.
There are a few older HBA devices that do not always succeed in logging in to a switch
port when the port speed is set for auto-neg otiate.
Workaround
If an older HBA has difficulty logging into a switch p ort that has its port speed
configured as Negotiate,configurethatportspeedto1Gb/sec or 2Gb/sec
according to the operation speed of the HBA connected to that port.
26