FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Director Release Notes (AA-RTDVG-TE/958-000276-007, March 2005)
Ports may accumulate spurious events
AportmayaccumulateInvalid transmission word and Bit-Error Threshold Link Incident
events when a tran
sceiver is poorly seated, resulting in a poor ground connection.
Workaround
Reseating the optical transceiver corrects the problem.
Possible switch reset after power failure or power off sequ ence
In extremely rare instances, after a power failure or power off sequence, an edge switch
or director configuration may be reset to factory default settings. This is evident when
HAFM is unable to communicate with the edge switch or director af ter being powered
on. This condition occurs because the IP address assigned to the edge switch or director
has been reset to the factory default value (10.1.1.10).
Workaround
If this condition occurs, the con figuration of the edge switch or director must be restored,
and the IP address must be restored. Also, all licensed features need to be reactivated
by entering the license keys again.
SNMP issues
SNMP traps warmStart and coldStart are not always received across Ethernet
switches.
Workaround
None.
HP StorageWorks Director release notes
27