FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Universal Port Module Kit Installation Instructions (AA-RSS2E-TE/958-000281-003, March 2005)

Installation instructions10
Supported UPM kits
HP sells the StorageWorks Director 2/64 with a base configuration of 32 Fibre Channel ports and
the StorageWorks Director 2/140 with a base configuration of 64 Fibre Channel ports. HP also
sells optional kits to increase the number of ports to a maximum of 64 for the Director 2/64 and a
maximum of 140 for the Director 2/140.
Use the procedures described in this chapter for the following UPM kits for both Director switches:
8-Port UPM Kit, 300833-B21 (A6574B), which contains (2) Short-wave, 4-port cards, which
includes (8) short-wave 2 Gbps SFP optical transceivers
4-Port UPM Kit, 316094-B21, which contains: (1) Short-wave, 4-port card, which includes (4)
short-wave 2 Gbps small form-factor pluggable (SFP) optical transceivers
Each kit also contains:
(1) Loop back plug (multi-mode/short wave)
(1) Port card installation instructions
•(1) Warranty
Installing UPM cards
This section describes procedures to install one UPM card. If you are installing more than one UPM
card, ensure that you perform the procedures for all UPM cards you install.
ESD information
CAUTION: To avoid causing machine errors or damage while working on the director, follow
ESD procedures by connecting a grounding cable to the director chassis and wearing an ESD wrist
strap.
The ESD grounding point for the front of the Director 2/64 chassis is located at the bottom
center, adjacent to the left power supply, as shown in Figure 1.
The ESD grounding points for the front of the Director 2/140 chassis are located at the front
and rear sides of the chassis, as shown in Figure 2.
The ESD grounding point for the rear of the Director 2/64 chassis is located at the bottom
center, directly below the maintenance port, as shown in Figure 3.
Touch the chassis once before performing any maintenance action, and once each minute while
installing UPMs. If the director is not connected to facility power (and therefore is not grounded),
connect the ESD wrist strap to an approved bench grounding point instead of the chassis.
Figure 1 shows a cable management assembly for the Director 2/64 that is used only with the
9000, 10000, and 11000 series cabinets.
For the Director 2/64, rotate the cable management assembly, if used, to reach the grounding
point. The assembly locks into the raised position. Any cables attached to the Director 2/64 are