FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Universal Port Module Kit Installation Instructions (AA-RSS2E-TE/958-000281-003, March 2005)
Universal port module kit installation instructions 13
The ESD grounding point for the rear of the Director 2/64 chassis is located at the bottom center,
directly below the maintenance port, as shown in Figure 3.
Figure 3 Director 2/64 ESD grounding point (rear)
Removing the UPM filler blank
Use the following procedure to remove a UPM filler blank. Filler blanks cover and protect unused
UPM card slots in the director chassis. The required tools are:
• Torque tool with hex adapter (provided with the director)
• ESD grounding cable and wrist strap
1. Attach a wrist strap to the director chassis.
CAUTION: To avoid causing machine errors or damage while working on the director, follow
ESD procedures by connecting a grounding cable to the director chassis and wearing an ESD wrist
strap.
2. If the director is rack-mounted and installed in a custom equipment cabinet, unlock and open
the cabinet front door. If the director is installed in a stand-alone configuration, go to step 3.
3. Identify the filler blank to be removed.
The filler blank is secured to the director chassis with two captive Allen screws. Both screws are
spring-loaded to lock the filler blank in place.
1 ESD Grounding Point
SHR-2300
1