FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks Universal Port Module Kit Installation Instructions (AA-RSS2E-TE/958-000281-003, March 2005)
Universal port module kit installation instructions 21
The following message appears:
Press START TEST to begin diagnostics.
The Next button changes to Start Test.
14.Click Start Test.
The test begins and:
• The Start Test button changes to Stop Test.
• The message Port xx: TEST RUNNING appears. The xx is the port number. If a UPM
card is tested, the message appears for all four ports.
• A red progress bar indicating percent completion travels from left to right across the
Completion Status field.
As an individual port is tested, the amber LED flashes (beacons) and the green LED illuminates
indicating loopback traffic through the port.
NOTE: IClick Stop Test at any time to abort the loopback test.
When the test completes, test results are displayed for each port tested as Port xx:
Passed! or Port xx: Failed! in the message area of the dialog box. If a port fails the
test, the amber LED for the port remains illuminated.
15.When finished, click Cancel to close the Port Diagnostics dialog box and return to the
Hardware View.
Beaconing is disabled for the port or UPM card.
16.Reset each tested port:
a. In the Hardware View, double-click the UPM card for which ports were tested.
The Port Card View appears.
b. In the Port Card View, right-click the tested port.
A menu appears.
c. Select Reset Port.
A Reset Port n message box appears, where n is the port number.
d. Click OK.
The port is reset.
17. Remove loopback plug(s) from the tested ports.
18.Reconnect fiber optic jumper cables from devices to tested ports.