FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
2
2-60
Intrepid® 6064 Director Installation and Service Manual
Installation Tasks
• If the director is online and switch binding is not enabled, all
WWNs of devices attached to the director are automatically
added to the membership list.
SANtegrity binding parameters have no effect on zoning
configurations. However, if a device WWN is in a specific zone, but
the WWN is not in the membership list, the device cannot log in to a
director port and cannot connect to other devices in the zone with
switch binding enabled.
Enable or Disable Switch Binding
Perform this procedure to configure (enable or disable) switch
binding:
1. Ensure the SANtegrity binding feature key is installed and
configured (Subtask D: Configure Feature Key on page 2-45).
2. At the Hardware View, select Switch Binding, then Change State
from the Configure menu. The Switch Binding - Change State dialog
box displays (Figure 2-47).
Figure 2-47 Switch Binding - Change State Dialog Box
3. Perform one of the following:
• To enable switch binding, click the Enable Switch Binding check
box to add a check mark. Go to step 4 to set the connection
policy.
• To disable switch binding, click the Enable Switch Binding
check box to remove the check mark, then click Activate to
enable the change and close the dialog box.
4. Select a Connection Policy radio button.
• Restrict E_Ports - Select this button to restrict connections
from specific fabric elements to director E_Ports. WWNs can
be added to the membership list to allow element connection