FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

2
2-92
Intrepid® 6064 Director Installation and Service Manual
Installation Tasks
Figure 2-70 Configure Panel (Director Page with Fabric Parameters Tab)
c. At the R_A_TOV field, type a value between 10 through 1200
tenths of a second (one through 120 seconds). Ten seconds
(100) is the recommended value.
NOTE: If the director is attached to a fabric element, the director and
element must be set to the same R_A_TOV value. If the values are not
identical, the E_Port connection to the element segments and the
director cannot communicate with the fabric. In addition, the
R_A_TOV value must be greater than the E_D_TOV value.
d. At the E_D_TOV field, type a value between 2 through 600
tenths of a second (0.2 through 60 seconds). Two seconds (20)
is the recommended value.
NOTE: If the director is attached to a fabric element, the director and
element must be set to the same E_D_TOV value. If the values are not
identical, the E_Port connection to the element segments and the
director cannot communicate with the fabric. In addition, the
E_D_TOV value must be less than the R_A_TOV value.
e. Select from the Switch Priority drop-down list to set the
director or switch priority. Available selections are Default,
Principal, and Never Principal. The default setting is Default.