FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
3
3-6
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
310 Cooling fan propeller recovered. No action required.
311 Cooling fan propeller recovered. No action required.
312 Cooling fan propeller recovered. No action required.
313 Cooling fan propeller recovered. No action required.
314 Cooling fan propeller recovered. No action required.
315 Cooling fan propeller recovered. No action required.
320 Fan module removed. Replace FRU.
321 Fan module installed. No action required.
400 Power-up diagnostic failure. Go to MAP 0200.
410 CTP card reset. No action required.
411 Firmware fault. Go to MAP 0200.
412 CTP watchdog timer reset. Go to Collecting
Maintenance Data on
page 4-39.
413 Backup CTP card POST failure. Go to MAP 0200.
414 Backup CTP card failed. Go to MAP 0500.
415 Backup CTP card removed. Replace FRU.
416 Backup CTP card installed. No action required.
417 CTP card firmware synchronization initiated. No action required.
418 User-initiated CTP card switchover. No action required.
420 Backup CTP card NV-RAM failure. Go to MAP 0500.
421 Firmware download complete. No action required.
422 CTP firmware synchronization complete. No action required.
423 CTP firmware download initiated. No action required.
426 Multiple ECC single-bit errors occurred. Go to MAP 0500.
430 Excessive Ethernet transmit errors. Go to MAP 0400.
Table 3-3 Event Codes versus Maintenance Action (continued)
Event
Code
Explanation Action