FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
3
Maintenance Analysis Procedures
3-7
Maintenance Analysis Procedures (MAPS)
431 Excessive Ethernet receive errors. Go to MAP 0400.
432 Ethernet adapter reset. Go to MAP 0400.
433 Non-recoverable Ethernet fault. Go to MAP 0500.
440 Embedded port hardware failed. Go to MAP 0500.
442 Embedded port anomaly detected. No action required.
445 ASIC detected a system anomaly. No action required.
450 Serial number mismatch detected. No action required.
451 Switch speed incompatibility detected. No action required.
452 Backup CTP incompatible with configured system
settings.
Replace backup CTP
card with a card that is
capable of supporting
the configured
settings, or adjust the
settings to be
compatible with the
backup CTP card.
453 New feature key installed. No action required.
500 Port card hot-insertion initiated. No action required.
501 Port card recognized. No action required.
502 Port module anomaly detected. No action required.
503 Port card hot-removal completed. No action required.
504 Port module failure. Go to MAP 0600.
505 Port module revision not supported. Go to MAP 0600.
506 Fibre Channel port failure. Go to MAP 0600.
507 Loopback diagnostics port failure. Go to MAP 0600.
508 Fibre Channel port anomaly detected. No action required.
510 SFP optical transceiver hot-insertion initiated. No action required.
512 SFP optical transceiver nonfatal error. Go to MAP 0600.
Table 3-3 Event Codes versus Maintenance Action (continued)
Event
Code
Explanation Action