FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
3-8
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
513 SFP optical transceiver hot-removal completed. No action required.
514 SFP optical transceiver failure. Go to MAP 0600.
581 Implicit incident. Go to MAP 0600.
582 Bit error threshold exceeded. Go to MAP 0600.
583 Loss of signal or loss of synchronization. Go to MAP 0600.
584 Not operational primitive sequence received. Go to MAP 0600.
585 Primitive sequence timeout. Go to MAP 0600.
586 Invalid primitive sequence received for current link
state.
Go to MAP 0600.
600 SBAR assembly hot-insertion initiated. No action required.
601 SBAR assembly recognized. No action required.
602 SBAR assembly anomaly detected. No action required.
603 SBAR assembly hot-removal completed. No action required.
604 SBAR assembly failure. Go to MAP 0500.
605 SBAR assembly revision not supported. Go to MAP 0500.
607 Director contains no operational SBAR assemblies. Go to MAP 0500.
608 User initiated SBAR switch-over. No action required.
800 High temperature warning (port module thermal
sensor).
Go to MAP 0600.
801 Critically hot temperature warning (port module thermal
sensor).
Go to MAP 0600.
802 Port module shutdown due to thermal violation. Go to MAP 0600.
805 High temperature warning (SBAR assembly thermal
sensor).
Go to MAP 0500.
806 Critically hot temperature warning (SBAR assembly
thermal sensor).
Go to MAP 0500.
807 SBAR assembly shutdown due to thermal violation. Go to MAP 0500.
Table 3-3 Event Codes versus Maintenance Action (continued)
Event
Code
Explanation Action