FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
MAP 0000: Start MAP
3-9
Maintenance Analysis Procedures (MAPS)
MAP 0000: Start MAP
This MAP describes initial fault isolation for the Intrepid 6064
Director. Fault isolation begins at the management server,
Internet-connected PC accessing the SANpilot interface,
customer-supplied server running the EFCM Lite application, failed
director, or director-attached host.
1
Prior to fault isolation, acquire the following information from the
customer:
A system configuration drawing or planning worksheet that
includes the management server, customer-supplied server
(accessing the SANpilot interface or running the EFCM Lite
application), directors and switches, other McDATA products,
and device connections.
The location of the management server or customer-supplied
server and all directors or switches.
The internet protocol (IP) address, gateway address, and subnet
mask for the director reporting the problem.
If performing fault isolation using the management server:
The Windows 2000 user name and password. These are
required when prompted during any MAP or repair
procedure that directs the management server to be
rebooted.
810 High temperature warning (CTP card thermal sensor). Go to MAP 0500.
811 Critically hot temperature warning (CTP card thermal
sensor).
Go to MAP 0500.
812 CTP card shutdown due to thermal violation. Go to MAP 0500.
850 System shutdown due to CTP card thermal violations. Go to MAP 0500.
Table 3-3 Event Codes versus Maintenance Action (continued)
Event
Code
Explanation Action