FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
3
MAP 0000: Start MAP
3-15
Maintenance Analysis Procedures (MAPS)
the status of the director or the status of the link between the
management server or customer-supplied server and the director:
• No status symbol indicates that the director is operational.
• A yellow triangle indicates that the director is operating in
degraded mode.
• A red diamond indicates that the director is not operational.
• A grey square with yellow exclamation mark indicates that the
status of the director is unknown.
Is a grey square with yellow exclamation mark associated with the
icon representing the director reporting the problem?
YES NO
↓ Go to step 11.
The status symbol indicates the management server or
customer-supplied server cannot communicate with the director
because:
• The director-to-server Ethernet link failed.
• AC power distribution in the director failed, or AC power was
disconnected.
• Both of the director control processor (CTP2) cards failed.
Continue.
8
Ensure the director reporting the problem is connected to facility AC
power and the power switch (circuit breaker) at the rear of the director
is set to the ON (up) position. Inspect the director for indications of
being powered on:
• At the front bezel, an illuminated power LED (green) or system
error LED (amber).
• An illuminated green LED on the active CTP2 card, and
illuminated green PWR OK LEDs on both power supplies.
• Audio emanations and airflow from cooling fans.
Does the director appear powered on?
YES NO
↓ A power distribution problem is indicated. Go to step 23 to
obtain event codes. If no event codes are found, go to MAP