FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
3
3-24
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
Was unit beaconing enabled because a director failure or degradation
was suspected?
YES NO
↓ The director appears operational. Exit MAP.
Go to step 24.
32
Is the system error LED (amber) at the director front bezel
illuminated?
YES NO
↓ The director appears operational. Verify operation at the
management server or customer-supplied server. Go to
step 3.
33
Check FRUs (port cards, CTP2 cards, SBAR assemblies, power
supplies, and fan modules) for failure symptoms.
Is the amber LED at the top of a port card illuminated or are any
amber LEDs associated with Fibre Channel ports illuminated?
NO YES
↓ A port card or Fibre Channel port failure is indicated. Go to
step 23 to obtain event codes. If no event codes are found,
go to MAP 0600: Port Card Failure and Link Incident Analysis
on page 3-83. Exit MAP.
34
Is the amber LED on a CTP2 card, SBAR assembly, or fan module
illuminated?
NO YES
↓ A FRU failure is indicated. Go to step 23 to obtain event
codes. If no event codes are found, go to MAP 0500: FRU
Failure Analysis on page 3-75. Exit MAP.