FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
MAP 0000: Start MAP
3-33
Maintenance Analysis Procedures (MAPS)
Figure 3-12 SANpilot Interface, Monitor Panel
Were one or more event codes found?
NO YES
Go to Table 3-3 on page 3-3 to interpret event codes.
Return to the MAP step that sent you here.
53
You are at the console of an open systems interconnection (OSI) or
Fibre Connection (FICON) server attached to the director reporting
the problem. If an incident occurs on the Fibre Channel link between
the director and server, a link incident record is generated and sent to
the server using the reporting procedure defined in T11/99-017v0
(OSI) or the FICON architecture document (FICON).
Was a link incident record generated and sent to the director-attached
OSI or FICON server?
YES NO
Perform director fault isolation at the management server or
customer-supplied server running the EFCM Lite application.
Go to step 3.