FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
3
3-42
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
• AC power distribution in the director failed, or AC power was
disconnected.
• Both of the director CTP2 cards failed.
Continue.
24
Ensure the director reporting the problem is connected to facility AC
power and the power switch (circuit breaker) at the rear of the director
is set to the ON (up) position. Inspect the director for indications of
being powered on:
• At the front bezel, an illuminated power LED (green) or system
error LED (amber).
• An illuminated green LED on the active CTP2 card.
• At least one green PWR OK LED illuminated on a power supply.
• Audio emanations and airflow from cooling fans.
Does the director appear powered on?
YES NO
↓ Go to step 14.
Analysis for an Ethernet link or dual CTP2 card failure is not
described in this MAP. Go to MAP 0000: Start MAP on page 3-9. If
this is the second time at this step, contact the next level of support.
Exit MAP.
25
Does the SANpilot interface appear operational?
NO YES
↓ Go to step 28.
26
A Page cannot be found, Unable to locate the server, HTTP 404 -
file not found, or other similar message appears. The message
indicates the web browser PC cannot communicate with the director
because:
• The director-to-PC Internet link could not be established.
• AC power distribution in the director failed, or AC power was
disconnected.
• Both of the director CTP2 cards failed.