FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
3
3-48
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
Did power supply replacement solve the problem?
NO YES
↓ The director appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
10
A port card failed POSTs (indicated by FRU codes 08 through 0F)
and must be removed and replaced (RRP: Port Module Card (UPM
and XPM) on page 5-11).
• This procedure is concurrent and can be performed while
director power is on.
• Perform the data collection procedure as part of FRU removal
and replacement.
Did port card replacement solve the problem?
NO YES
↓ The director appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
11
POST/IPL diagnostics detected a firmware failure and performed an
online dump. All Fibre Channel ports reset after the failure and
devices momentarily logout, login, and resume operation.
Perform the data collection procedure and return the CD to McDATA
for analysis. Exit MAP.
12
The backup CTP2 card failed POST/IPL diagnostics, and must be
removed and replaced (RRP: CTP2 Card on page 5-7).
• This procedure is concurrent and can be performed while
director power is on.
• Perform the data collection procedure as part of FRU removal
and replacement.
ATTENTION! Do not remove and replace a redundant CTP2 card if the
backup CTP2 card is not fully operational and director power is on. The
director IP address, configuration data, and other operating parameters will
be lost.