FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
3
3-68
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
Figure 3-23 COMn Properties Dialog Box
h. Configure the Port Settings parameters as follows:
— Bits per second - 57600.
— Data bits - 8.
—Parity - None.
— Stop bits - 1.
— Flow control - Hardware or None.
When the parameters are set, click OK. The Intrepid 6064 -
HyperTerminal dialog box displays.
i. At the > prompt, type the user-level password (the default is
password) and press Enter. The password is case sensitive.
The Intrepid 6064 - HyperTerminal dialog box displays with a C>
prompt at the bottom of the window.
j. At the C> prompt, type ipconfig and press Enter. The Intrepid
6064 - HyperTerminal dialog box (Figure 3-24) displays with
configuration information listed, including the IP address.