FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
3
MAP 0500: FRU Failure Analysis
3-75
Maintenance Analysis Procedures (MAPS)
Does the SANpilot interface appear operational with the View panel
displayed?
NO YES
↓ The director-to-SANpilot PC connection is restored and
appears operational. Exit MAP.
Failure of the CTP2 card Ethernet port is indicated. Go to MAP 0500:
FRU Failure Analysis on page 3-75. Exit MAP.
MAP 0500: FRU Failure Analysis
This MAP describes fault isolation for the CTP2 card, SBAR assembly,
and fan module. Failure indicators include:
• An event code recorded at the Intrepid 6064 Event Log
(management server) or the SANpilot event log.
• The amber LED on the FRU illuminates.
• An amber emulated LED on a FRU graphic at the Hardware View
illuminates.
• A blinking red and yellow diamond (failed FRU indicator)
appears over a FRU graphic; or a grey square (status unknown
indicator) or yellow triangle (attention indicator) appears at the
alert panel of the Hardware View.
•A Failed message associated with a FRU at the SANpilot
interface.
1
Was an event code 300, 301, 302, 303, 304, 305, 414, 420, 426, 433,
440, 604, 605, 607, 805, 806, 807, 810, 811, 812, or 850 observed at
the Intrepid 6064 Event Log or at the SANpilot event log?
YES NO
↓ Go to step 3.