FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
3-76
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
2
Tabl e 3-9 lists event codes, brief explanations of the codes, and
associated steps that describe fault isolation procedures.
Table 3-9 MAP 500: Event Codes
Event
Code
Explanation Action
300 Cooling fan propeller failed. Go to step 5.
301 Cooling fan propeller failed. Go to step 5.
302 Cooling fan propeller failed. Go to step 5.
303 Cooling fan propeller failed. Go to step 5.
304 Cooling fan propeller failed. Go to step 5.
305 Cooling fan propeller failed. Go to step 5.
414 Backup CTP2 card failed. Go to step 7.
420 Backup CTP2 card NV-RAM failure. Go to step 7.
426 Multiple ECC single-bit errors occurred. Go to step 7.
433 Non-recoverable Ethernet fault. Go to step 7.
440 Embedded port hardware failed. Go to step 7.
604 SBAR assembly failure. Go to step 9.
605 SBAR assembly revision not supported. Go to step 16.
607 Director contains no operational SBAR assemblies. Go to step 9.
805 High temperature warning (SBAR assembly thermal
sensor).
Go to step 9.
806 Critically hot temperature warning (SBAR assembly
thermal sensor).
Go to step 9.
807 SBAR assembly shutdown due to thermal violation. Go to step 9.
810 High temperature warning (CTP2 card thermal
sensor).
Go to step 7.