FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
MAP 0500: FRU Failure Analysis
3-79
Maintenance Analysis Procedures (MAPS)
Is the amber LED on an SBAR assembly illuminated but not blinking
(beaconing)?
YES NO
The director appears operational. Exit MAP.
9
An SBAR assembly failed and must be removed and replaced (RRP:
SBAR Assembly on page 5-26).
This procedure is concurrent and can be performed while
director power is on.
Perform the data collection procedure as part of FRU removal
and replacement.
Did SBAR assembly replacement solve the problem?
NO YES
The director appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
10
Is fault isolation being performed at the management server or
customer-supplied server?
YES NO
Fault isolation is being performed at the SANpilot interface.
Go to step 18.
11
Does a blinking red and yellow diamond (failed FRU indicator) appear
to overlay a fan module graphic at the Hardware View?
NO YES
A fan module failure is indicated. Go to step 5.
12
Does a blinking red and yellow diamond (failed FRU indicator) appear
to overlay a CTP2 card graphic at the Hardware View?
NO YES
A CTP2 card failure is indicated. Go to step 7.