FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
3
3-80
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
13
Does a blinking red and yellow diamond (failed FRU indicator) appear
to overlay an SBAR assembly graphic at the Hardware View?
NO YES
↓ An SBAR assembly failure is indicated. Go to step 9.
14
At the Hardware View, does a grey square appear at the alert panel, a
No Link status appear at the Intrepid 6064 Status table, and
graphical FRUs appear uninstalled?
YES NO
↓ A green circle appears at the alert panel and the director
appears operational. Exit MAP.
The grey square indicates the management server or
customer-supplied server cannot communicate with the director
because:
• The director-to-server Ethernet link failed.
• AC power distribution in the director failed, or AC power was
disconnected.
• Both of the director CTP2 cards failed.
Continue.
15
At the director, inspect the amber LED at the top of each CTP2 card.
Is the amber LED illuminated on both CTP2 cards?
NO YES
↓ Failure of both CTP2 cards is indicated. Go to step 7.
Analysis for an Ethernet link or AC power distribution failure is not
described in this MAP. Go to MAP 0000: Start MAP on page 3-9. If
this is the second time at this step, contact the next level of support.
Exit MAP.
16
An SBAR assembly is not recognized by director firmware because
the firmware version is not supported or the SBAR assembly failed.
Advise the customer of the problem and determine the correct