FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
3-82
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
At least one green PWR OK LED illuminated on a power supply.
Audio emanations and airflow from cooling fans.
Does the director appear powered on?
YES NO
Analysis for an AC power distribution failure is not described
in this MAP. Go to MAP 0000: Start MAP on page 3-9. If this
is the second time at this step, contact the next level of
support. Exit MAP.
21
At the director, inspect the amber LED at the top of each CTP2 card.
Is the amber LED illuminated on both CTP2 cards?
NO YES
Failure of both CTP2 cards is indicated. Go to step 7.
Analysis for an Ethernet link failure is not described in this MAP. Go to
MAP 0000: Start MAP on page 3-9. If this is the second time at this
step, contact the next level of support. Exit MAP.
22
Inspect fan module operational states at the SANpilot interface.
a. At the View panel, click the FRU Properties tab. The View panel
(FRU Properties tab) displays.
b. Inspect the Status fields for both fan modules.
Does the Status field display a Failed message for either fan module?
NO YES
A fan module failure is indicated. Go to step 5.
23
Inspect CTP2 card operational states at the SANpilot interface.
Inspect the Status fields for both CTP2 cards.
Does the Status field display a Failed message for either CTP2 card?
NO YES
A CTP2 card failure is indicated. Go to step 7.
24
Inspect SBAR assembly operational states at the SANpilot interface.
Inspect the Status fields for both assemblies.