FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
MAP 0600: Port Card Failure and Link Incident Analysis
3-83
Maintenance Analysis Procedures (MAPS)
Does the Status field display a Failed message for either SBAR
assembly?
NO YES
An SBAR assembly failure is indicated. Go to step 9.
The director appears operational. Exit MAP.
MAP 0600: Port Card Failure and Link Incident Analysis
This MAP describes fault isolation for UPM and XPM cards, SFP and
XFP optical transceivers, and Fibre Channel link incidents. Failure
indicators include:
An event code recorded at the Intrepid 6064 Event Log or the
SANpilot event log.
One or more amber LEDs on the port card illuminate.
One or more emulated amber LEDs on a port card graphic at the
Hardware View illuminate.
A blinking red and yellow diamond (failed FRU indicator)
appears over a port card graphic or a yellow triangle (attention
indicator) appears at the alert panel of the Hardware View.
A port operational state message or a Failed message associated
with a port card at the SANpilot interface.
A link incident message recorded in the Link Incident Log or Port
Properties dialog box.
A link incident event code recorded at the console of an OSI or
FICON server attached to the director reporting the problem.
1
Was an event code 080, 081, 504, 505, 506, 507, 512, 514, 800, 801,
or 802 observed at the Intrepid 6064 Event Log (management server)
or at the SANpilot event log?
NO YES
Go to step 3.
2
Was an event code 581, 582, 583, 584, 585, or 586 observed at the
console of an OSI or FICON server attached to the director reporting
the problem?