FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
3
3-84
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
YES NO
↓ Go to step 4.
3
Tabl e 3-10 lists event codes, brief explanations of the codes, and
associated steps that describe fault isolation procedures.
Table 3-10 MAP 600: Event Codes
Event
Code
Explanation Action
080 Unauthorized worldwide name. Go to step 18.
081 Invalid attachment. Go to step 19.
504 Port card failure. Go to step 6.
505 Port card revision not supported. Go to step 40.
506 Fibre Channel port failure. Go to step 6.
507 Loopback diagnostics port failure. Go to step 14.
512 SFP/XFP optical transceiver nonfatal error. Go to step 6.
514 SFP/XFP optical transceiver failure. Go to step 6.
581 Implicit incident. Go to step 33.
582 Bit error threshold exceeded. Go to step 33.
583 Loss of signal or loss of synchronization. Go to step 33.
584 Not operational primitive sequence received. Go to step 33.
585 Primitive sequence timeout. Go to step 33.
586 Invalid primitive sequence received for current link state. Go to step 33.
800 High temperature warning (port card thermal sensor). Go to step 7.
801 Critically hot temperature warning (port card thermal
sensor).
Go to step 7.
802 Port card shutdown due to thermal violation. Go to step 7.