FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)
3
MAP 0600: Port Card Failure and Link Incident Analysis
3-85
Maintenance Analysis Procedures (MAPS)
4
Is fault isolation being performed at the director?
YES NO
↓ Fault isolation is being performed at the management server,
customer-supplied server, or SANpilot interface. Go to
step 8.
5
Inspect the faceplates of port cards at the front of the director. Each
card has an amber LED (at the top of the card) that illuminates if the
card fails or if any Fibre Channel port fails.
Each card also has a bank of amber and green LEDs above the ports.
Each LED pair is associated with a corresponding port (e.g. the top
LED pair is associated with the top port). The amber LED illuminates
and the green LED extinguishes if the port fails.
Are an amber port LED and the amber LED at the top of the port card
illuminated but not blinking (beaconing)?
YES NO
↓ The director appears operational, however a link incident or
other problem may have occurred. Perform fault isolation at
the management server or customer-supplied server. Go to
step 8.
6
A Fibre Channel port failed, and the SFP optical transceiver must be
removed and replaced (RRP: Optical Transceiver (SFP and XFP) on
page 5-17).
• This procedure is concurrent and can be performed while
director power is on.
• Verify the location of the failed port. Figure 3-32 and Figure 3-33
show UPM card numbers (0 through15), port numbers (00
through 63), and bolded logical port addresses (hexadecimal 04
through 43).