FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
3-88
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
12
Inspect the port state and LED status for all ports with an attention
indicator.
a. At the Hardware View, double-click the port graphic with the
attention indicator. The Port Properties dialog box displays.
b. Inspect the Operational State field at the Port Properties dialog
box, and the emulated green and amber LEDs adjacent to the
port at the Hardware View.
c. Table 3-11 lists LED and port operational state combinations and
associated MAP 0600 (or other) steps that describe fault
isolation procedures.
13
A link incident may have occurred, but the LIN alerts option is not
enabled for the port and the attention indicator does not appear.
At the Hardware View, click Logs and select Link Incident Log. The
Link Incident Log displays. If a link incident occurred, the affected port
number is listed with one of the following messages.
Link interface incident - implicit incident.
Table 3-11 Port Operational and LED States (Management Server)
Operational State Green LED Amber LED Action
Offline Off Off Go to step 16.
Not Operational Off Off Go to step 16.
Testing Off Blinking Internal loopback test in
process. Exit MAP.
Testing On Blinking External loopback test in
process. Exit MAP.
Beaconing Off or On Blinking Go to step 17.
Invalid Attachment On Off Go to step 19.
Link Reset Off Off Go to step 32.
Link Incident Off Off Go to step 33.
Segmented E_Port On Off Go to MAP 0700.