FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
3-94
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
22
A loopback (wrap) plug is connected to the port and there is no
diagnostic test running. Is a loopback plug in the port receptacle?
YES NO
Contact the next level of support. Exit MAP.
23
Remove the loopback plug from the port receptacle. If directed by the
customer, connect a fiber-optic jumper cable attaching a device to the
director.
If the port is operational and a device is not attached, both LEDs
adjacent to the port extinguish and the port state is No Light.
If the port is operational and a device is attached, the green
LED illuminates, the amber LED extinguishes, and the port state
is Online.
Did removing the loopback plug solve the problem?
NO YES
The director appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
24
A port connection timed out because of an unresponsive device
(node) or an ISL connection was not allowed because of a security
violation (authorization failure reject). Check the port status and clean
the fiber-optic connectors on the cable.
a. Notify the customer the port will be blocked. Ensure the
customer system administrator quiesces Fibre Channel frame
traffic through the port and sets the attached device offline.
b. Block the port (Blocking and Unblocking Ports on page 4-46).
c. Disconnect both ends of the fiber-optic cable.
d. Clean the fiber-optic connectors (Cleaning Fiber-Optic
Components on page 4-51).
e. Reconnect the fiber-optic cable.
f. Unblock the port (Blocking and Unblocking Ports on page 4-46).
g. Monitor port operation for approximately five minutes.