FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
MAP 0600: Port Card Failure and Link Incident Analysis
3-97
Maintenance Analysis Procedures (MAPS)
Figure 3-36 Fabric Binding Dialog Box
b. At the Fabric List section, ensure the Enable/Disable checkbox is
enabled (checked) for the fabric containing both directors or
switches.
c. At the Membership List of <Fabric Name> section, update the
membership list for both elements to ensure interswitch
compatibility, then click OK. The fabric binding feature is
consistently enabled for both directors or switches.
Did updating the fabric membership lists solve the problem?
The director appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
30
A port connection is not allowed because of a switch binding
mismatch. Switch membership lists must be compatible for both fabric
elements.
a. At the Hardware View for each director or switch, click Configure
and select Switch Binding and Edit Membership List. The Switch
Binding - Membership List dialog box displays (Figure 3-37).