3
MAP 0600: Port Card Failure and Link Incident Analysis
3-103
Maintenance Analysis Procedures (MAPS)
Does the director appear powered on?
YES NO
Analysis for an Ethernet link, AC power distribution, or dual
CTP2 card failure is not described in this MAP. Go to MAP
0000: Start MAP on page 3-9. If this is the second time at
this step, contact the next level of support. Exit MAP.
45
Inspect port card operational states at the SANpilot interface.
a. At the View panel, click the FRU Properties tab. The View panel
(FRU Properties tab) displays.
b. Inspect the Status fields for port cards. Scroll down the View
panel as necessary.
Does the Status field display a Failed message for a port card?
NO YES
A port card failure is indicated. Go to step 7.
46
Inspect Fibre Channel port operational states at the SANpilot
interface.
a. At the View panel, click the Port Properties tab. The View panel
(Port Properties tab) displays with port 0 highlighted in red.
b. Click the port number (0 through 63) for which a failure is
suspected to display properties for that port.
c. Inspect the Operational State field. Scroll down the View panel
as necessary.
d. Tabl e 3 -13 lists port operational states and associated MAP
0600 steps that describe fault isolation procedures.
Table 3-13 MAP 600: Port Operational States and Actions (SANpilot)
Operational State Action
Offline Go to step 16.
Not Operational Go to step 16.
Port Failure Go to step 6.
Testing Internal or external loopback test in process. Exit MAP.
Invalid Attachment Go to step 19.