FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
3-104
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
47
Install an SFP optical transceiver in the port receptacle (RRP: Optical
Transceiver (SFP and XFP) on page 5-17).
a. This procedure is concurrent and can be performed while
director power is on.
b. Verify the location of the failed port. Figure 3-39 and Figure 3-40
show the UPM card numbers (0 through 15), port numbers (00
through 63), and bolded logical port addresses (hexadecimal 04
through 43).
c. Perform an external loopback test for the port as part of FRU
removal and replacement (External Loopback Test
(Management Server) on page 4-32).
Exit MAP.
Figure 3-39 UPM Card Diagram (OSI)
Link Reset Go to step 32.
Not Installed Go to step 47.
Table 3-13 MAP 600: Port Operational States and Actions (SANpilot)
Operational State Action