FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
3-108
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
7
A minor error occurred that caused fabric services databases to be
re-initialized to an empty state. As a result, a disruptive fabric logout
and login occurred for all attached devices. The following list explains
the errors.
Event code 010 - Following a CTP2 card reset, the login server
attempted to acquire a fabric server database copy from the
other CTP2 card and failed.
Event code 011 - Following a CTP2 card failover, the login
server database failed cyclic redundancy check (CRC)
validation.
Event code 020 - Following a CTP2 card reset, the name server
attempted to acquire a fabric server database copy from the
other CTP2 card and failed.
Event code 021 - Following CTP2 card failover, the name server
failed database CRC validation.
All attached devices resume operation after fabric login. Perform the
data collection procedure and return the CD to McDATA for analysis.
Exit MAP.
8
A minor error occurred that caused management server database to
be re-initialized to an empty state. As a result, a disruptive server
logout and login occurred for all attached devices. The following list
explains the errors.
Event code 050 - Following CTP2 card reset, the management
server attempted to acquire a database copy from the other
CTP2 card and failed.
Build fabric protocol error. Go to step 17.
No principal switch. Go to step 19.
No response from attached switch. Go to step 20.
Table 3-15 Port Segmentation Reasons and Actions (Management
Server) (continued)
Segmentation Reason Action