FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
3-110
Intrepid® 6064 Director Installation and Service Manual
Maintenance Analysis Procedures (MAPS)
Intrepid 6140 Director in a multiswitch fabric that has more than
70 ISLs attached.
Other fabric element (other than an Intrepid 6140 Director) in a
multiswitch fabric that has more than 32 ISLs attached.
Fibre Channel frames may be lost or routed in loops because of
potential fabric routing problems. Advise the customer of the problem
and work with the system administrator to reconfigure the fabric so
that no switch or switch elements have more than the proscribed
number of ISLs.
Did fabric reconfiguration solve the problem?
NO YES
The director and multiswitch fabric appear operational.
Exit MAP.
Contact the next level of support. Exit MAP.
12
A 070 event code indicates an E_Port detected an incompatibility with
an attached director and prevented the directors from forming a
multiswitch fabric. A segmented E_port cannot transmit Class 2 or
Class 3 Fibre Channel traffic.
A 071 event code indicates the director is isolated from all directors in
a multiswitch fabric, and is accompanied by a 070 event code for
each segmented E_Port. The 071 event code is resolved when all
070 events are corrected.
Obtain supplementary event data for each 070 event code.
a. At the Hardware View, click Logs and select Event Log. The
Event Log displays.
b. Examine the first five bytes (0 through 4) of event data.
c. Byte 0 specifies the director port number (00 through 63) of the
segmented E_port. Byte 4 specifies the segmentation reason
(Tabl e 3-16 ).
Table 3-16 Byte 4, Segmentation Reasons, and Actions
Byte 4 Segmentation Reason Action
01 Incompatible operating parameters. Go to step 14.
02 Duplicate domain IDs. Go to step 15.
03 Incompatible zoning configurations. Go to step 16.