FW 07.00.00/HAFM SW 08.06.00 McDATA Intrepid 6064 Director Installation and Service Manual (620-000108-920, April 2005)

3
MAP 0700: Fabric, ISL, and Segmented Port Problem Determination
3-111
Maintenance Analysis Procedures (MAPS)
13
A director E_Port is connected to an unsupported switch or fabric
element.
Advise the customer of the problem and disconnect the interswitch
link to the unsupported switch. Exit MAP.
14
A director E_Port segmented because the error detect time out value
(E_D_TOV) or resource allocation time out value (R_A_TOV) is
incompatible with the attached fabric element.
a. Contact McDATA customer support or engineering personnel to
determine the recommended E_D_TOV and R_A_TOV values
for both directors or switches.
b. Notify the customer both directors will be set offline. Ensure the
system administrator quiesces Fibre Channel frame traffic
through the directors or switches, and sets attached devices
offline.
c. Set both directors or switches offline (Set the Director Online or
Offline on page 4-43).
d. At the Hardware View for the first director or switch reporting the
problem, click Configure and select Operating Parameters and
Fabric Parameters. The Configure Fabric Parameters dialog box
displays (Figure 3-41).
04 Build fabric protocol error. Go to step 17.
05 No principal switch. Go to step 19.
06 No response from attached switch. Go to step 20.
Table 3-16 Byte 4, Segmentation Reasons, and Actions (continued)
Byte 4 Segmentation Reason Action